This was in a guesthouse bathroom, there was a showerhead pointed right at it.

  • Cheradenine@sh.itjust.worksOP
    link
    fedilink
    English
    arrow-up
    18
    ·
    2 days ago

    This is a 20 amp circuit breaker, not only is it unprotected, when it failed someone bypassed it instead of replacing it with something correct. If you took a shower in the morning and water splashed on these open contacts you wouldn’t need coffee to get your heart started.

    • ChaoticNeutralCzech@feddit.org
      link
      fedilink
      English
      arrow-up
      3
      ·
      edit-2
      1 day ago

      Is it a suicide shower (the kind where an unprotected 3000W+ heating wire runs through the water) with disconnected ground? (A grill around the nozzles is connected to a ground wire that is supposed to prevent the current from flowing into your body, but it tends to trip GFCI/RCD so stupid desperate people disconnect it against the advice in the manual. If they were desperate but smarter, they would connect the grill to neutral instead to prevent GFCI/RCD from tripping while maintaining slightly better leakage prevention.)

      • Cheradenine@sh.itjust.worksOP
        link
        fedilink
        English
        arrow-up
        4
        ·
        1 day ago

        No it wasn’t one of those, though I have gotten a surprise from them a few times.

        This was a small wall mounted unit with a thermoblock heater. There was no ground of course.

    • krashmo@lemmy.world
      link
      fedilink
      arrow-up
      6
      ·
      2 days ago

      Ignoring all the obvious bad decisions, what were they trying to accomplish? Even if that was wired correctly in a breaker panel enclosure I can’t figure out why it would be placed in a location that had a shower head pointed at it.

      • Cheradenine@sh.itjust.worksOP
        link
        fedilink
        English
        arrow-up
        8
        ·
        2 days ago

        Honestly I thought about it and I’m not sure what the intention was. It could have been mounted on the other side of the wall (outside the bathroom) just as easily.

        I’ll have to dig it up but I have a photo of the old electric meter from the same place. It was buzzing quite loudly, then it melted. It would have been marginal when installed and was connected to only lights and ceiling fans, then they did a reno and added aircon and water heaters.

    • AnyOldName3@lemmy.world
      link
      fedilink
      arrow-up
      4
      ·
      2 days ago

      It doesn’t really even need an exception. Working means disconnecting when more than 20 A are drawn, and this doesn’t do that. The rule works just fine, and counterexamples always boil down to someone misunderstanding the design goals and using a bad definition of works.

      • Voroxpete@sh.itjust.works
        link
        fedilink
        arrow-up
        2
        ·
        2 days ago

        Yeah, I’d argue that even taken more broadly any shower that kills the occupants cannot be said to “work” by any reasonable definition.

        Obviously, we can all think of one very notable and very unreasonable definition, but I doubt that was the intention here.

  • ridago@programming.dev
    link
    fedilink
    arrow-up
    2
    ·
    2 days ago

    I’d argue this is not an exception, just a misunderstanding of what “works” means. Clearly the “protecting wires in case of overload” function is not working…